产品详情
-
联系我们
The TPT1051 is a CAN transceiver that meets theISO11898 high-speed CAN (Controller Area Network)physical layer standard. The device is designed to be usedin CAN FD networks up to 5 Mbps, with enhanced timingmargin and higher data rates in long and highly loadednetworks. As designed, the device features crosswire,overvoltage, and loss of ground protection from −70 V to+70 V, over-temperature shutdown, with a −30 V to +30V common-mode input voltage range. The TPT1051V hasa secondary power supply input for I/O level shifting theinput pin thresholds and RXD output level. This family hasa silent mode which is also commonly referred to as thelisten-only mode. Additionally, all devices include manyprotection features to enhance the device and networkrobustness.The TPT1051 and TPT1051V are available in SOP8 andDFN3X3-8L packages and are characterized from −40°Cto +125°C.
Features
• Meets the ISO 11898-2:2016 and SAE J2284-1 to SAEJ2284-5 Physical Layer Standards
• Supports CAN FD and Data Rating up to 5 Mbps
• Short Propagation Delay Times and Fast Loop Times
• 5-V Power Supply, I/O Voltage Range Supports 2.8-Vto 5.5-V MCU Interface
• Ideal Passive Behavior to CAN Bus when Unpowered
• Common-Mode Input Voltage: ±30 V
• Protection Feature:
– IEC 61000-4-2 ESD Protection up to ±15 kV
– Bus Fault Protection: ±70 V
– VCC and VIO (V variants only) Under-voltageProtection
– TXD Dominant Time-out Function and BusDominant Time-out Function
– Thermal Shutdown Protection
• Available in SOP8 Package and Leadless DFN3X3Package
Applications
• All Devices Supporting Highly Loaded CAN Networks
• Field Industrial Automation, Sensor and Driver Systems
• Building, Security Control Systems
• Energy Storage Systems
• Telecom Base Station Status and Control
Features
• Meets the ISO 11898-2:2016 and SAE J2284-1 to SAEJ2284-5 Physical Layer Standards
• Supports CAN FD and Data Rating up to 5 Mbps
• Short Propagation Delay Times and Fast Loop Times
• 5-V Power Supply, I/O Voltage Range Supports 2.8-Vto 5.5-V MCU Interface
• Ideal Passive Behavior to CAN Bus when Unpowered
• Common-Mode Input Voltage: ±30 V
• Protection Feature:
– IEC 61000-4-2 ESD Protection up to ±15 kV
– Bus Fault Protection: ±70 V
– VCC and VIO (V variants only) Under-voltageProtection
– TXD Dominant Time-out Function and BusDominant Time-out Function
– Thermal Shutdown Protection
• Available in SOP8 Package and Leadless DFN3X3Package
Applications
• All Devices Supporting Highly Loaded CAN Networks
• Field Industrial Automation, Sensor and Driver Systems
• Building, Security Control Systems
• Energy Storage Systems
• Telecom Base Station Status and Control