产品详情
-
联系我们
TPC6240 is a precision 8-/16-channel, multiplexed ADCwith integrated PGA and many other features, offeringaccurate measurement for low-bandwidth input signals,and lower-system cost and component count.The device has a 24-bit delta-sigma converter, withconfigurable data rates. There are sinc5 filter for optimizednosie performance, and low-latency filter for fast settlingwith 50-/60-Hz rejection for noisy industrial environments.A low-noise programmable gain amplifer provides 1~128gain options to amplify low-level signals.Additionaly, it integrates a precision 2.5-V band gapreference and integrated oscillator.Two programmable exitation current souces are availablefor easy RTD biasing for temperature measurement.Finally, more features such as burn out, CRC, voltage bias,system monitoring, and GPIOs are integrated.The device is available in QFN6X6-40 package.
Features
• ADC Performance:
– Analog Multiplexer with 8-full Differential or 16-single Ended Inputs
– Programmable Amplifier Programmable Gain: 1 to128
– Low Noise: nVRMS
– Programmable Data Rates: 2.5 SPS to 8 kSPS
– Digital Filter: Simultaneous 50-Hz and 60-HzRejection at ≤ 20 SPS with Low-Latency DigitalFilter
• Integrated Functions:
– Dual-Matched Programmable Current Sources forSensor Excitation: 10 µA to 2000 µA
– Internal Reference: 2.5 V– Internal Oscillator
– Internal Temperature Sensor
– Extended Fault Detection Circuits
– Self Offset and System Calibration
– GPIO and GPO pins with external mux control
• Digital Interface
– 3-/4- wire SPI-Compatible Interface with CRCChecking
• Digital Supply: 2.7 V to 5 V
• Package: 40-lead 6mm x 6 mm QFN
• Operating Temperature: –40°C to +125°C
Applications
• Process Control: PLC/DCS Modules
• Voltage, Current, Temperature, and Pressure Measurement Flow Meters
• Temperature Controllers
• Medical and Scientific Instrumentation
Features
• ADC Performance:
– Analog Multiplexer with 8-full Differential or 16-single Ended Inputs
– Programmable Amplifier Programmable Gain: 1 to128
– Low Noise: nVRMS
– Programmable Data Rates: 2.5 SPS to 8 kSPS
– Digital Filter: Simultaneous 50-Hz and 60-HzRejection at ≤ 20 SPS with Low-Latency DigitalFilter
• Integrated Functions:
– Dual-Matched Programmable Current Sources forSensor Excitation: 10 µA to 2000 µA
– Internal Reference: 2.5 V– Internal Oscillator
– Internal Temperature Sensor
– Extended Fault Detection Circuits
– Self Offset and System Calibration
– GPIO and GPO pins with external mux control
• Digital Interface
– 3-/4- wire SPI-Compatible Interface with CRCChecking
• Digital Supply: 2.7 V to 5 V
• Package: 40-lead 6mm x 6 mm QFN
• Operating Temperature: –40°C to +125°C
Applications
• Process Control: PLC/DCS Modules
• Voltage, Current, Temperature, and Pressure Measurement Flow Meters
• Temperature Controllers
• Medical and Scientific Instrumentation